Input and Output Overview

 

Connectivity Komplex Sequencer

PER SEQUENCER INPUTS/OUTPUTS

Trigger inputs are 0-5V. Most CV Inputs are 0-5V as well. If the input has a corresponding rotary control, then the input becomes the bias of the rotary control and accepts bipolar signals. Trigger Outputs are 0-5V in general.

1. CV OUT (Output)
The CV output of the sequencer.

2. GATE OUT (Output)
Outputs a positive gate per step where gate is engaged.

3. SOS OUT (Start of Sequence) (Trigger Output)
Sends a pulse every time a Start signal is received by the sequencer. A pulse is also send when the start button is pressed.

4. EOS OUT (End of Sequence) (Trigger Output)
Outputs a pulse every time the sequence hits the end of its last step.

5. CLOCK IN ( Trigger Input)
Set the speed of sequencer via an incoming clock signal. Overrides the Speed rotary control.

6. CLOCK OUT (Trigger Output)
Outputs the clock per sequencer as set by Speed or incoming clock.

7. REC CLK (Trigger Input)
Set the speed of the corresponding CV Recorder output via an incoming clock signal. The Clock Out is normalled to this input.

8. REC OUT (CV Output)
CV output of the corresponding CV Recorder bank (A, B, C or D).

9. TRANSP (CV Input)
Offsets the whole sequence’s CV output by the amount of CV applied. To transpose with V/oct use the Quantizer on the CV outputs. Accepts Bipolar Signals.

10. START (Trigger Input)
When this input receives a positive pulse, the sequence starts playing or pauses.

11. STOP (Trigger Input)
An incoming pulse resets the sequence back to its Sequence Start Point.

12. SKIP STEP (Trigger Input)
When positive voltage is applied to this input, the step is skipped in accordance with the Skip Step setting in the Mode Menu.

13. SSP (CV Input)
Sets the sequence start point.

14. REPEATS (CV Input)
Sets the amount of repeats for steps with repeat active with CV.

15. SEQ LGTH (CV Input)
Adds positive/negative offset to the manually set Sequence Length. Accepts Bipolar Signals. 

16. GATE LGTH (CV Input)
Adds positive/negative offset to the manually set Gate Length. Accepts Bipolar Signals.

17. PLAY M (CV Input)
Adds positive/negative offset to the manually set Play Mode of the sequence. Accepts Bipolar Signals.

18. GLIDE (CV Input)
Adds positive/negative offset to the manually set Glide time. Accepts Bipolar Signals.

19. DIVISION (CV Input)
Adds positive/negative offset to the manually set Division. Accepts Bipolar Signals.

GENERAL INPUTS/OUTPUTS

20. MIDI IN (Input)
Receives incoming MIDI clock and MIDI Start and STOP messages

21. MIDI OUT (Output)
Sends MIDI information (MIDI Pitch Mode, MIDI Velocity Mode or MIDI CC Mode) as assigned by the four sequencers in the Mode Menu.

22. MIDI CLK (Output)
The MIDI-to-analog clock out sends a trigger (+5V) after 24 MIDI clock pulses are received corresponding to 1 clock trigger per quarter note.

23. AC 12V (Power Adapter)
Only use the KOMA adapter shipped with the unit. The Komplex powers on automatically when plugged in.